Home / Products / R513A / Specification

R513A Refrigerant Specification

Technical Data Sheet(TDS) R-513A(HFC/HFO blend) CH₂FCF₃ / CF₃CF=CH₂( 44/56) R513A, and.

Document No.:ZJ-TDS-R513A-2026 Version:V1.0 Issue date2026-09-24 Next review:2027-09-24

1 Product Identification

Item Value
Product NameR513A Refrigerant
Chemical NameR-513A(HFC/HFO blend)
English NameR-513A(HFC/HFO blend)
Molecular FormulaCH₂FCF₃ / CF₃CF=CH₂( 44/56)
Molecular Weightapprox. 108.7
CAS Registry Number811-97-2 / 754-12-1
EINECS No.212-377-0 / 468-710-7
UN Number3163
Transport Hazard ClassClass 2.2, non-flammable gas
ASHRAE Safety ClassificationA1(Low toxicity, non-flammable)
Reference BasisManufacturer data; the batch COA governs

Reference Basis: Compiled from manufacturer data (safety classification per GB/T 7778, ASHRAE 34 / ISO 817)

2 Physical & Chemical Properties

R513A Typicaldata, system and,.

Item Typical Value
AppearanceColorless, transparent liquefied gas
OdorFaint, non-irritating
Bubble point(101.3 kPa)-29.0 ℃
Temperature glide< 0.1 ℃(Near-azeotropic)
Critical Temperatureapprox. 96.5 ℃
Critical Pressureapprox. 3.79 MPa
Vapor Pressure (25 C, absolute)0.665 MPa
Liquid Density(25 ℃)approx. 1140 kg/m³
Saturated Vapor Density(25 ℃)approx. 33.5 kg/m³
Latent heat of vaporisation (at bubble point)approx. 195 kJ/kg
Liquid Specific Heat(25 ℃)approx. 1.40 kJ/(kg K)
Vapor Specific Heat(25 ℃, 101.3 kPa)approx. 0.86 kJ/(kg K)
Liquid Thermal Conductivity(25 ℃)approx. 0.079 W/(m K)
Vapor Thermal Conductivity(25 ℃)approx. 0.0138 W/(m K)
Liquid Viscosity(25 ℃)approx. 0.17 mPa s
Vapor Viscosity(25 ℃)approx. 0.0117 mPa s
Surface Tension(25 ℃)approx. 8.4 mN/m
Water Solubility(25 ℃)Slightly soluble
Auto-Ignition TemperatureNot applicable (non-flammable)
Flammability Limits in Air (vol.%)None (non-flammable)
OEL (8 h TWA)approx. 700 ppm(per)
Ozone Depletion Potential (ODP)0
GWP (100 yr, IPCC AR5)573
Atmospheric Lifetimeapprox. 14 years( R134a )

3 Quality Specifications & Test Methods

R513A Parameter, Batch COA.

Item Parameter Test Method
AppearanceColourless and clear, free of suspended matter and mechanical impuritiesVisual inspection
Purity≥ 99.90 %Gas chromatography GC-FID
Composition toleranceR134a ±1.0 %, R1234yf ±1.0 %Gas chromatography GC-FID
Moisture≤ 10 ppmKarl Fischer coulometric method
Acidity( HF )≤ 0.1 ppmAlkali absorption - potentiometric titration
Evaporation Residue≤ 0.01 %Gravimetric method
Non-Condensable Gas(, 25 ℃)≤ 1.5 %Gas chromatography
(Cl⁻)Negative (pass)Silver nitrate turbidimetry

4 Comparison with Common Refrigerants

Comparison Item R513A(this product) R134a R1234yf
CompositionR1234yf/R134a 56/44Single compound CH₂FCF₃Single compound HFO-1234yf
ODP000
GWP(100 years, AR5)5731430< 1
ASHRAE Safety ClassificationA1(Non-flammable)A1A2L(Mildly flammable)
Boiling point-29.0 ℃-26.3 ℃-29.4 ℃
Temperature glide< 0.1 ℃(Near-azeotropic)0 ℃0 ℃
Relative cooling capacityapprox. 96 % ~ 100 %Baseline 100 %approx. 93 % ~ 98 %
Relative COPand R134aBaselineLow, approx. -2 % ~ -5 %
Compatible lubricantPOEPOEPOE / PVE
Retrofit feasibilityR134aOriginal fluid in existing systemsrequires dedicated equipment, not directly retrofittable
Current selectionR134a low-GWPand commercial refrigerationexisting installed baseair conditioning Regulations

5 Packaging Specifications

Package Type Specification Filling Ratio Valve Connection Application
disposable cylinder10 kg(customizable 5 kg / 20 kg)≤ 0.95 kg/LW21.8-14(customizable CGA / DIN)Servicing and small-batch use
steel cylinder400 kg(T )≤ 0.95 kg/LW21.8-14bulk supply
cylinder pallet12 × 10 kgPer cylinderW21.8-14serviceservice networkdistribution
ISO ISO tankapprox. 18 tper ISO tankISO tankconnectionand Transport

Filling Ratioper"", steel cylinderper.

6 Applications

  • commercial refrigeration and display cabinet
  • chiller, heat pump and Medium temperaturesystem
  • R134a system low-GWP retrofit
  • air conditioning and Transport(per A1 existing installed base equipmentretrofit)

Equipment Compatibility & Charging Advice

  • R513A and R134a A1, existing installed base equipment, Maincharging and.
  • POE, R134a system POE, retrofit and.
  • Near-azeotropic Mixture( < 0.1 ℃), Spillage,,.
  • R134a approx. 96 % ~ 100 %, per equipment charging.
  • retrofitrecovery refrigerant, and R134a or Other refrigerantcharging.

7 Storage & Transport

  • Storage,, ventilation, 40 ℃, ignition source, heat source and.
  • steel cylinder, and,,, and.
  • R513A A1 Non-flammable refrigerant, Vapour, Spillagelow-lying areasoxygen, ventilation.
  • and oxygen, and (,, )Flammable.
  • and, Low 0.05 MPa.
  • Transportper Danger 2.2 class, and, steel cylinder.

8 Safety & Handling

  • Asphyxiation riskVapour, Spillagelow-lying areas, and equipmentoxygen, ventilationoxygen(Low 19.5 %).
  • SpillageSpillageventilation,;;leak detection or leak detection, open flamesleak detection.
  • Thermal decomposition riskopen flames or High temperature(approx. 400 ℃ and above),, recoveryventilation.
  • FirefightingR513A ASHRAE 34 Non-flammable, steel cylinder Risk;steel cylinder.
  • frostbite ProtectionLiquefied gasfrostbite, and;frostbite 40 ℃.
  • Inhalation andVapourasphyxiation and, fresh airoxygen;Eye contact 15.

9 Quality Assurance & Shipping Documents

  • Batch COA, Purity( or ), Moisture, Acidity and Evaporation Residue.
  • Moisture, and Low temperature.
  • 12 months, Batch, No. and.
  • perthird-party test report(SGS / ), SDS Description REACH, RoHS.

10 Frequently Asked Questions

R513A Can it directly replace R134a ?

. R513A and R134a, A1 Non-flammable, existing installed base equipment, Mainrecovery R134a, percharging,. POE.

R513A and R1234yf How to choose?

low-GWP, R1234yf(GWP < 1), A2L Mildly flammable, explosion-proof and Spillage;existing installed base R134a equipmentretrofit, Non-flammable, R513A(GWP 573, A1).

R513A Can it be topped up after a leak?

. R513A Near-azeotropic Mixture, Temperature glide 0.1 ℃, Spillage, per, R407C Zeotropic refrigerant.

R513A Shelf life?

steel cylinder, Storage, R513A Shelf Life 24 months., steel cylinder and.

Disclaimer
Specificationdata Typical,;Parameter Batch COA. and, or or, equipment and Regulations.

| Reviewed by: | Approved by: | Hubei Zhongjin Fluorine Chemical Co., Ltd.

Get R513A Technical Data Sheet & Quotation

Word Specification and, or Direct Contact sales teamGetBatch Test Report and Quotation.