R512A Refrigerant Specification
Technical Data Sheet(TDS) R-512A(HFC/HFO blend) CH₂FCF₃ / CF₃CF=CH₂( 5/95) R512A, and.
1 Product Identification
| Item | Value |
|---|---|
| Product Name | R512A Refrigerant |
| Chemical Name | R-512A(HFC/HFO blend) |
| English Name | R-512A(HFC/HFO blend) |
| Molecular Formula | CH₂FCF₃ / CF₃CF=CH₂( 5/95) |
| Molecular Weight | approx. 113.4 |
| CAS Registry Number | 811-97-2 / 754-12-1 |
| EINECS No. | 212-377-0 / 468-710-7 |
| UN Number | 3163 |
| Transport Hazard Class | Class 2.2, non-flammable gas |
| ASHRAE Safety Classification | A1(Low toxicity, non-flammable) |
| Reference Basis | Manufacturer data; the batch COA governs |
Reference Basis: Compiled from manufacturer data (safety classification per GB/T 7778, ASHRAE 34 / ISO 817)
2 Physical & Chemical Properties
R512A Typicaldata, system and,.
| Item | Typical Value |
|---|---|
| Appearance | Colorless, transparent liquefied gas |
| Odor | Faint, non-irritating |
| Bubble point(101.3 kPa) | approx. -29.2 ℃ |
| Temperature glide | < 1 ℃(Near-azeotropic) |
| Critical Temperature | approx. 95 ℃ |
| Critical Pressure | approx. 3.36 MPa |
| Vapor Pressure (25 C, absolute) | approx. 0.68 MPa |
| Liquid Density(25 ℃) | approx. 1095 kg/m³ |
| Saturated Vapor Density(25 ℃) | approx. 33 kg/m³ |
| Latent heat of vaporisation (at bubble point) | approx. 182 kJ/kg |
| Liquid Specific Heat(25 ℃) | approx. 1.39 kJ/(kg K) |
| Vapor Specific Heat(25 ℃, 101.3 kPa) | approx. 0.88 kJ/(kg K) |
| Liquid Thermal Conductivity(25 ℃) | approx. 0.076 W/(m K) |
| Vapor Thermal Conductivity(25 ℃) | approx. 0.0136 W/(m K) |
| Liquid Viscosity(25 ℃) | approx. 0.16 mPa s |
| Vapor Viscosity(25 ℃) | approx. 0.0118 mPa s |
| Surface Tension(25 ℃) | approx. 8.2 mN/m |
| Water Solubility(25 ℃) | Slightly soluble |
| Auto-Ignition Temperature | Not applicable (non-flammable) |
| Flammability Limits in Air (vol.%) | None (non-flammable) |
| OEL (8 h TWA) | approx. 510 ppm(per) |
| Ozone Depletion Potential (ODP) | 0 |
| GWP (100 yr, IPCC AR5) | 188 |
| Atmospheric Lifetime | approx. 1 years( R134a ) |
3 Quality Specifications & Test Methods
R512A Parameter, Batch COA.
| Item | Parameter | Test Method |
|---|---|---|
| Appearance | Colourless and clear, free of suspended matter and mechanical impurities | Visual inspection |
| Purity | ≥ 99.90 % | Gas chromatography GC-FID |
| Composition tolerance | R134a ±0.5 %, R1234yf ±1.0 % | Gas chromatography GC-FID |
| Moisture | ≤ 10 ppm | Karl Fischer coulometric method |
| Acidity( HF ) | ≤ 0.1 ppm | Alkali absorption - potentiometric titration |
| Evaporation Residue | ≤ 0.01 % | Gravimetric method |
| Non-Condensable Gas(, 25 ℃) | ≤ 1.5 % | Gas chromatography |
| (Cl⁻) | Negative (pass) | Silver nitrate turbidimetry |
4 Comparison with Common Refrigerants
| Comparison Item | R512A(this product) | R134a | R513A |
|---|---|---|---|
| Composition | R134a/R152a 5/95 | Single compound CH₂FCF₃ | R1234yf/R134a 56/44 |
| ODP | 0 | 0 | 0 |
| GWP(100 years, AR5) | 188 | 1430 | 573 |
| ASHRAE Safety Classification | A1(Non-flammable) | A1 | A1 |
| Boiling point | approx. -29.2 ℃ | -26.3 ℃ | -29.0 ℃ |
| Temperature glide | < 1 ℃ | 0 ℃ | < 0.1 ℃ |
| Relative cooling capacity | Low R134a | Baseline 100 % | approx. 96 % ~ 100 % |
| Compatible lubricant | POE | POE | POE |
| Retrofit feasibility | R134a | Original fluid in existing systems | R134a |
| Current selection | ultra-low-GWP Medium temperature Alternatives | existing installed base, phase-down | low-GWP retrofit |
5 Packaging Specifications
| Package Type | Specification | Filling Ratio | Valve Connection | Application |
|---|---|---|---|---|
| disposable cylinder | 10 kg(customizable 5 kg / 20 kg) | ≤ 0.95 kg/L | W21.8-14(customizable CGA / DIN) | Servicing and small-batch use |
| steel cylinder | 400 kg(T ) | ≤ 0.95 kg/L | W21.8-14 | bulk supply |
| cylinder pallet | 12 × 10 kg | Per cylinder | W21.8-14 | serviceservice networkdistribution |
| ISO ISO tank | approx. 18 t | per ISO tank | ISO tankconnection | and Transport |
Filling Ratioper"", steel cylinderper.
6 Applications
- Medium temperature commercial refrigeration and
- chiller and heat pumpsystem
- R134a system ultra-low-GWP retrofit
- GWP equipment
Equipment Compatibility & Charging Advice
- R512A and R134a A1, R134a equipment, percharging.
- POE, retrofit.
- Near-azeotropic Mixture( < 1 ℃), Spillage,.
- Low R134a, system.
- retrofitrecovery refrigerant, and R134a or Other refrigerantcharging.
7 Storage & Transport
- Storage,, ventilation, 40 ℃, ignition source, heat source and.
- steel cylinder, and,,, and.
- R512A A1 Non-flammable refrigerant, Vapour, Spillagelow-lying areasoxygen, ventilation.
- and oxygen, and (,, )Flammable.
- and, Low 0.05 MPa.
- Transportper Danger 2.2 class, and, steel cylinder.
8 Safety & Handling
- Asphyxiation riskVapour, Spillagelow-lying areas, and equipmentoxygen, ventilationoxygen(Low 19.5 %).
- SpillageSpillageventilation,;;leak detection or leak detection, open flamesleak detection.
- Thermal decomposition riskopen flames or High temperature(approx. 400 ℃ and above),, recoveryventilation.
- FirefightingR512A ASHRAE 34 Non-flammable, steel cylinder Risk;steel cylinder.
- frostbite ProtectionLiquefied gasfrostbite, and;frostbite 40 ℃.
- Inhalation andVapourasphyxiation and, fresh airoxygen;Eye contact 15.
9 Quality Assurance & Shipping Documents
- Batch COA, Purity( or ), Moisture, Acidity and Evaporation Residue.
- Moisture, and Low temperature.
- 12 months, Batch, No. and.
- perthird-party test report(SGS / ), SDS Description REACH, RoHS.
10 Frequently Asked Questions
R512A and R513A How to choose?
R134a and R1234yf Mixture A1,: R512A 5/95, GWP 188, ParameterLow;R513A 44/56, GWP 573, and R134a. Item GWP (EU 150 and below), R512A;, R513A.
R512A Can it directly replace R134a ?
. R512A and R134a, A1 Non-flammable, POE, Mainrecovery refrigerant, percharging. Low R134a,.
R512A GWP 188 EURegulations?
EU F-Gas Regulationsair conditioning GWP 150, R512A 188 Slightly higher than, commercial refrigeration equipment. Regulations.
R512A Shelf life?
steel cylinder, Storage, R512A Shelf Life 24 months., steel cylinder and.
Specificationdata Typical,;Parameter Batch COA. and, or or, equipment and Regulations.
| Reviewed by: | Approved by: | Hubei Zhongjin Fluorine Chemical Co., Ltd.
Get R512A Technical Data Sheet & Quotation
Word Specification and, or Direct Contact sales teamGetBatch Test Report and Quotation.