Home / Products / R512A / Specification

R512A Refrigerant Specification

Technical Data Sheet(TDS) R-512A(HFC/HFO blend) CH₂FCF₃ / CF₃CF=CH₂( 5/95) R512A, and.

Document No.:ZJ-TDS-R512A-2026 Version:V1.0 Issue date2026-09-24 Next review:2027-09-24

1 Product Identification

Item Value
Product NameR512A Refrigerant
Chemical NameR-512A(HFC/HFO blend)
English NameR-512A(HFC/HFO blend)
Molecular FormulaCH₂FCF₃ / CF₃CF=CH₂( 5/95)
Molecular Weightapprox. 113.4
CAS Registry Number811-97-2 / 754-12-1
EINECS No.212-377-0 / 468-710-7
UN Number3163
Transport Hazard ClassClass 2.2, non-flammable gas
ASHRAE Safety ClassificationA1(Low toxicity, non-flammable)
Reference BasisManufacturer data; the batch COA governs

Reference Basis: Compiled from manufacturer data (safety classification per GB/T 7778, ASHRAE 34 / ISO 817)

2 Physical & Chemical Properties

R512A Typicaldata, system and,.

Item Typical Value
AppearanceColorless, transparent liquefied gas
OdorFaint, non-irritating
Bubble point(101.3 kPa)approx. -29.2 ℃
Temperature glide< 1 ℃(Near-azeotropic)
Critical Temperatureapprox. 95 ℃
Critical Pressureapprox. 3.36 MPa
Vapor Pressure (25 C, absolute)approx. 0.68 MPa
Liquid Density(25 ℃)approx. 1095 kg/m³
Saturated Vapor Density(25 ℃)approx. 33 kg/m³
Latent heat of vaporisation (at bubble point)approx. 182 kJ/kg
Liquid Specific Heat(25 ℃)approx. 1.39 kJ/(kg K)
Vapor Specific Heat(25 ℃, 101.3 kPa)approx. 0.88 kJ/(kg K)
Liquid Thermal Conductivity(25 ℃)approx. 0.076 W/(m K)
Vapor Thermal Conductivity(25 ℃)approx. 0.0136 W/(m K)
Liquid Viscosity(25 ℃)approx. 0.16 mPa s
Vapor Viscosity(25 ℃)approx. 0.0118 mPa s
Surface Tension(25 ℃)approx. 8.2 mN/m
Water Solubility(25 ℃)Slightly soluble
Auto-Ignition TemperatureNot applicable (non-flammable)
Flammability Limits in Air (vol.%)None (non-flammable)
OEL (8 h TWA)approx. 510 ppm(per)
Ozone Depletion Potential (ODP)0
GWP (100 yr, IPCC AR5)188
Atmospheric Lifetimeapprox. 1 years( R134a )

3 Quality Specifications & Test Methods

R512A Parameter, Batch COA.

Item Parameter Test Method
AppearanceColourless and clear, free of suspended matter and mechanical impuritiesVisual inspection
Purity≥ 99.90 %Gas chromatography GC-FID
Composition toleranceR134a ±0.5 %, R1234yf ±1.0 %Gas chromatography GC-FID
Moisture≤ 10 ppmKarl Fischer coulometric method
Acidity( HF )≤ 0.1 ppmAlkali absorption - potentiometric titration
Evaporation Residue≤ 0.01 %Gravimetric method
Non-Condensable Gas(, 25 ℃)≤ 1.5 %Gas chromatography
(Cl⁻)Negative (pass)Silver nitrate turbidimetry

4 Comparison with Common Refrigerants

Comparison Item R512A(this product) R134a R513A
CompositionR134a/R152a 5/95Single compound CH₂FCF₃R1234yf/R134a 56/44
ODP000
GWP(100 years, AR5)1881430573
ASHRAE Safety ClassificationA1(Non-flammable)A1A1
Boiling pointapprox. -29.2 ℃-26.3 ℃-29.0 ℃
Temperature glide< 1 ℃0 ℃< 0.1 ℃
Relative cooling capacityLow R134aBaseline 100 %approx. 96 % ~ 100 %
Compatible lubricantPOEPOEPOE
Retrofit feasibilityR134aOriginal fluid in existing systemsR134a
Current selectionultra-low-GWP Medium temperature Alternativesexisting installed base, phase-downlow-GWP retrofit

5 Packaging Specifications

Package Type Specification Filling Ratio Valve Connection Application
disposable cylinder10 kg(customizable 5 kg / 20 kg)≤ 0.95 kg/LW21.8-14(customizable CGA / DIN)Servicing and small-batch use
steel cylinder400 kg(T )≤ 0.95 kg/LW21.8-14bulk supply
cylinder pallet12 × 10 kgPer cylinderW21.8-14serviceservice networkdistribution
ISO ISO tankapprox. 18 tper ISO tankISO tankconnectionand Transport

Filling Ratioper"", steel cylinderper.

6 Applications

  • Medium temperature commercial refrigeration and
  • chiller and heat pumpsystem
  • R134a system ultra-low-GWP retrofit
  • GWP equipment

Equipment Compatibility & Charging Advice

  • R512A and R134a A1, R134a equipment, percharging.
  • POE, retrofit.
  • Near-azeotropic Mixture( < 1 ℃), Spillage,.
  • Low R134a, system.
  • retrofitrecovery refrigerant, and R134a or Other refrigerantcharging.

7 Storage & Transport

  • Storage,, ventilation, 40 ℃, ignition source, heat source and.
  • steel cylinder, and,,, and.
  • R512A A1 Non-flammable refrigerant, Vapour, Spillagelow-lying areasoxygen, ventilation.
  • and oxygen, and (,, )Flammable.
  • and, Low 0.05 MPa.
  • Transportper Danger 2.2 class, and, steel cylinder.

8 Safety & Handling

  • Asphyxiation riskVapour, Spillagelow-lying areas, and equipmentoxygen, ventilationoxygen(Low 19.5 %).
  • SpillageSpillageventilation,;;leak detection or leak detection, open flamesleak detection.
  • Thermal decomposition riskopen flames or High temperature(approx. 400 ℃ and above),, recoveryventilation.
  • FirefightingR512A ASHRAE 34 Non-flammable, steel cylinder Risk;steel cylinder.
  • frostbite ProtectionLiquefied gasfrostbite, and;frostbite 40 ℃.
  • Inhalation andVapourasphyxiation and, fresh airoxygen;Eye contact 15.

9 Quality Assurance & Shipping Documents

  • Batch COA, Purity( or ), Moisture, Acidity and Evaporation Residue.
  • Moisture, and Low temperature.
  • 12 months, Batch, No. and.
  • perthird-party test report(SGS / ), SDS Description REACH, RoHS.

10 Frequently Asked Questions

R512A and R513A How to choose?

R134a and R1234yf Mixture A1,: R512A 5/95, GWP 188, ParameterLow;R513A 44/56, GWP 573, and R134a. Item GWP (EU 150 and below), R512A;, R513A.

R512A Can it directly replace R134a ?

. R512A and R134a, A1 Non-flammable, POE, Mainrecovery refrigerant, percharging. Low R134a,.

R512A GWP 188 EURegulations?

EU F-Gas Regulationsair conditioning GWP 150, R512A 188 Slightly higher than, commercial refrigeration equipment. Regulations.

R512A Shelf life?

steel cylinder, Storage, R512A Shelf Life 24 months., steel cylinder and.

Disclaimer
Specificationdata Typical,;Parameter Batch COA. and, or or, equipment and Regulations.

| Reviewed by: | Approved by: | Hubei Zhongjin Fluorine Chemical Co., Ltd.

Get R512A Technical Data Sheet & Quotation

Word Specification and, or Direct Contact sales teamGetBatch Test Report and Quotation.