Home / Products / R508B / Specification

R508B Refrigerant Specification

Technical Data Sheet(TDS) R-508B(Azeotropic HFC blend) CHF₃ / CF₃CF₃( 46/54) R508B, and.

Document No.:ZJ-TDS-R508B-2026 Version:V1.0 Issue date2026-09-24 Next review:2027-09-24

1 Product Identification

Item Value
Product NameR508B Refrigerant
Chemical NameR-508B(Azeotropic HFC blend)
English NameR-508B(Azeotropic HFC blend)
Molecular FormulaCHF₃ / CF₃CF₃( 46/54)
Molecular Weightapprox. 95.4
CAS Registry Number75-46-7 / 76-16-4
EINECS No.200-872-4 / 200-939-8
UN Number3163
Transport Hazard ClassClass 2.2, non-flammable gas
ASHRAE Safety ClassificationA1(Low toxicity, non-flammable)
Reference BasisManufacturer data; the batch COA governs

Reference Basis: Compiled from manufacturer data (safety classification per GB/T 7778, ASHRAE 34 / ISO 817)

2 Physical & Chemical Properties

R508B Typicaldata, system and,.

Item Typical Value
AppearanceColorless, transparent liquefied gas
OdorFaint, non-irritating
Boiling Point (101.3 kPa)approx. -87.4 ℃
Temperature glide≈ 0 ℃(Azeotropic)
Critical Temperatureapprox. 21 ℃
Critical Pressureapprox. 4.13 MPa
Vapor Pressure (25 C, absolute)approx. 3.3 MPa
Liquid Density(-40 ℃)approx. 1250 kg/m³
Saturated Vapor Density(25 ℃)approx. 135 kg/m³
Latent Heat of Vaporization (at boiling point)approx. 155 kJ/kg
Liquid Specific Heat(25 ℃)approx. 1.30 kJ/(kg K)
Vapor Specific Heat(25 ℃, 101.3 kPa)approx. 0.75 kJ/(kg K)
Liquid Thermal Conductivity(25 ℃)approx. 0.090 W/(m K)
Vapor Thermal Conductivity(25 ℃)approx. 0.0155 W/(m K)
Liquid Viscosity(25 ℃)approx. 0.09 mPa s
Vapor Viscosity(25 ℃)approx. 0.0160 mPa s
Surface Tension(25 ℃)approx. 3.5 mN/m
Water Solubility(25 ℃)Slightly soluble
Auto-Ignition TemperatureNot applicable (non-flammable)
Flammability Limits in Air (vol.%)None (non-flammable)
Typical evaporating temperature-80 ℃ ~ -100 ℃
OEL (8 h TWA)1000 ppm
Ozone Depletion Potential (ODP)0
GWP (100 yr, IPCC AR5)13396
Atmospheric Lifetimeapprox. 1000 yearsand above( R116 )

3 Quality Specifications & Test Methods

R508B Parameter, Batch COA.

Item Parameter Test Method
AppearanceColourless and clear, free of suspended matter and mechanical impuritiesVisual inspection
Purity≥ 99.90 %Gas chromatography GC-FID
Composition toleranceR23 ±1.0 %, R116 ±1.0 %Gas chromatography GC-FID
Moisture≤ 10 ppmKarl Fischer coulometric method
Acidity( HF )≤ 0.1 ppmAlkali absorption - potentiometric titration
Evaporation Residue≤ 0.01 %Gravimetric method
Non-Condensable Gas(, 25 ℃)≤ 1.5 %Gas chromatography
(Cl⁻)Negative (pass)Silver nitrate turbidimetry

4 Comparison with Common Refrigerants

Comparison Item R508B(this product) R23 R14
CompositionR23/R116 46/54 AzeotropicSingle compound CHF₃Single compound CF₄
Boiling pointapprox. -87.4 ℃-82.1 ℃-127.8 ℃
Typical evaporating temperature-80 ℃ ~ -100 ℃-70 ℃ ~ -85 ℃120 ℃ and below
ODP000
GWP(100 years, AR5)13396148007390
ASHRAE Safety ClassificationA1A1A1
Temperature glide≈ 0 ℃(Azeotropic)0 ℃0 ℃
Compatible lubricantPOE(Low temperature)POE(Low temperature)POE(Low temperature)
systemLow stage of cascade systemsLow stage of cascade systemscascade/cascadeLow temperature
Current selectionUltra-low temperature cascadesystem refrigerantcryogenic and Low temperaturetestingLow temperaturecryogenic

5 Packaging Specifications

Package Type Specification Filling Ratio Valve Connection Application
disposable cylinder10 kg(customizable 5 kg)≤ 0.70 kg/LW21.8-14(customizable CGA / DIN)Servicing and small-batch use
steel cylinder40 kg(customizable 100 kg)≤ 0.70 kg/LW21.8-14equipmentbulk supply
cylinder palletMade to orderPer cylinderW21.8-14Itemdistribution
ISO ISO tankMade to orderper ISO tankISO tankconnectionand Transport

Filling Ratioper"", steel cylinderper.

6 Applications

  • pharmaceuticalchemicalcryogenic and freeze drying
  • Low temperaturetest chamber and environmental test equipment
  • gas liquefaction and Low temperature
  • cascade Ultra-low temperaturesystem Low temperature

Equipment Compatibility & Charging Advice

  • R508B cascade Ultra-low temperaturesystem Low temperature, High temperature R404A, R507 or R134a, per cascadecondensing.
  • GWP refrigerant(13396), cryogenic, recovery and tightness, emissions.
  • Low temperature POE, per Ultra-low temperaturecompressor and.
  • system and, Low temperature and.
  • Low temperature, system and,.

7 Storage & Transport

  • Storage,, ventilation, 40 ℃, ignition source, heat source and.
  • steel cylinder, and,,, and.
  • R508B A1 Non-flammable refrigerant, Vapour, Spillagelow-lying areasoxygen, ventilation.
  • and oxygen, and (,, )Flammable.
  • and, Low 0.05 MPa.
  • Transportper Danger 2.2 class, and, steel cylinder.

8 Safety & Handling

  • Asphyxiation riskVapour, Spillagelow-lying areas, and equipmentoxygen, ventilationoxygen(Low 19.5 %).
  • Overpressure riskR508B Critical TemperatureLow(approx. 21 ℃), steel cylinder,, or, system and.
  • SpillageSpillageventilation,;;leak detection or leak detection, open flamesleak detection.
  • Thermal decomposition riskopen flames or High temperature, recoveryventilation.
  • frostbite ProtectionLiquefied gasfrostbite, Evaporating temperatureLow, and;frostbite 40 ℃.
  • Inhalation andVapourasphyxiation and, fresh airoxygen;Eye contact 15.

9 Quality Assurance & Shipping Documents

  • Batch COA, Purity( or ), Moisture, Acidity and Evaporation Residue.
  • Moisture, and Low temperature.
  • 12 months, Batch, No. and.
  • perthird-party test report(SGS / ), SDS Description REACH, RoHS.

10 Frequently Asked Questions

80 ℃ and below R23 R508B?

R23 -70 ℃ ~ -85 ℃, R508B Azeotropic Mixture -80 ℃ ~ -100 ℃, Low temperature. -120 ℃ and below Low temperature, R14 or cascade. Evaporating temperature, and compressor.

R508B GWP 13396 ?

. R508B GWP refrigerant, "Kigali Amendment"phase-down, cryogenic, recovery, and Spillage, Itemlow-GWP Ultra-low temperature Alternatives.

R508B systemWhy is?

R508B Critical Temperatureapprox. 21 ℃, refrigerant,. Ultra-low temperaturesystem( or ) and, perLow temperature refrigerant.

R508B Shelf life?

steel cylinder, Storage, R508B Shelf Life 24 months., steel cylinder and.

Disclaimer
Specificationdata Typical,;Parameter Batch COA. and, or or, equipment and Regulations.

| Reviewed by: | Approved by: | Hubei Zhongjin Fluorine Chemical Co., Ltd.

Get R508B Technical Data Sheet & Quotation

Word Specification and, or Direct Contact sales teamGetBatch Test Report and Quotation.