R507 Refrigerant Technical Data Sheet
Technical Data Sheet(TDS) R-507(Azeotropic HFC blend) CHF₂CF₃ / CF₃CH₂F( 50/50) R507, and.
1 Product Identification
| Item | Value |
|---|---|
| Product Name | R507 Refrigerant |
| Chemical Name | R-507(Azeotropic HFC blend) |
| English Name | R-507(Azeotropic HFC blend) |
| Molecular Formula | CHF₂CF₃ / CF₃CH₂F( 50/50) |
| Molecular Weight | 98.90 |
| CAS Registry Number | 354-33-6 / 420-46-2 |
| EINECS No. | 206-557-8 / 206-996-5 |
| UN Number | 3163 |
| Transport Hazard Class | Class 2.2, non-flammable gas |
| ASHRAE Safety Classification | A1(Low toxicity, non-flammable) |
| Reference Basis | Manufacturer data; the batch COA governs |
Reference Basis: Compiled from manufacturer data (safety classification per GB/T 7778, ASHRAE 34 / ISO 817)
2 Physical & Chemical Properties
R507 Typicaldata, system and,.
| Item | Typical Value |
|---|---|
| Appearance | Colorless, transparent liquefied gas |
| Odor | Slight ethereal odor, non-irritating |
| Boiling Point (101.3 kPa) | -46.7 ℃ |
| Temperature glide | 0 ℃(Azeotropic) |
| Critical Temperature | 70.6 ℃ |
| Critical Pressure | 3.79 MPa |
| Critical Density | approx. 490 kg/m³ |
| Vapor Pressure (25 C, absolute) | 1.28 MPa |
| Liquid Density(25 ℃) | 1043 kg/m³ |
| Saturated Vapor Density(25 ℃) | 48.1 kg/m³ |
| Latent Heat of Vaporization (at boiling point) | approx. 197 kJ/kg |
| Liquid Specific Heat(25 ℃) | 1.52 kJ/(kg·K) |
| Vapor Specific Heat(25 ℃, 101.3 kPa) | 0.86 kJ/(kg·K) |
| Liquid Thermal Conductivity(25 ℃) | 0.083 W/(m·K) |
| Vapor Thermal Conductivity(25 ℃) | 0.0146 W/(m·K) |
| Liquid Viscosity(25 ℃) | 0.15 mPa·s |
| Vapor Viscosity(25 ℃) | 0.0133 mPa·s |
| Surface Tension(25 ℃) | 7.5 mN/m |
| Water Solubility(25 ℃) | Slightly soluble |
| Auto-Ignition Temperature | Not applicable (non-flammable) |
| Flammability Limits in Air (vol.%) | None (non-flammable) |
| OEL (8 h TWA) | 1000 ppm |
| Ozone Depletion Potential (ODP) | 0 |
| GWP (100 yr, IPCC AR5) | 3985 |
| Atmospheric Lifetime | approx. 31 years(per) |
3 Quality Specifications & Test Methods
R507 Parameter, Batch COA.
| Item | Parameter | Test Method |
|---|---|---|
| Appearance | Colourless and clear, free of suspended matter and mechanical impurities | Visual inspection |
| Purity | ≥ 99.90 % | Gas chromatography GC-FID |
| Composition tolerance | R125 ±1.0 %, R143a ±1.0 % | Gas chromatography GC-FID |
| Moisture | ≤ 10 ppm | Karl Fischer coulometric method |
| Acidity( HCl ) | ≤ 0.1 ppm | Alkali absorption - potentiometric titration |
| Evaporation Residue | ≤ 0.01 % | Gravimetric method |
| Non-Condensable Gas(, 25 ℃) | ≤ 1.5 % | Gas chromatography |
| (Cl⁻) | Negative (pass) | Silver nitrate turbidimetry |
4 Comparison with Common Refrigerants
| Comparison Item | R507(this product) | R404A | R452A |
|---|---|---|---|
| Composition | R125/R143a 50/50 Azeotropic | R125/R143a/R134a 44/52/4 | R32/R125/R1234yf 11/59/30 |
| ODP | 0 | 0 | 0 |
| GWP(100 years, AR5) | 3985 | 3922 | 1945 |
| ASHRAE Safety Classification | A1 | A1 | A1 |
| Temperature glide | 0 ℃(Azeotropic) | approx. 0.8 ℃ | approx. 3 ℃ |
| Relative cooling capacity | Slightly higher than R404A, approx. +2 % ~ +5 % | Baseline 100 % | and R404A |
| Spillage | Azeotropic | Near-azeotropic | Zeotropic |
| Compatible lubricant | POE | POE | POE |
| Current selection | Low temperature Azeotropic refrigerant | Low temperaturesystemexisting installed base | low-GWP Alternatives |
5 Packaging Specifications
| Package Type | Specification | Filling Ratio | Valve Connection | Application |
|---|---|---|---|---|
| disposable cylinder | 10.9 kg(customizable 9.5 kg) | ≤ 0.85 kg/L | W21.8-14(customizable CGA / DIN) | Servicing and small-batch use |
| steel cylinder | 400 kg(T ) | ≤ 0.85 kg/L | W21.8-14 | Bulk project supply |
| cylinder pallet | 12 × 10.9 kg | Per cylinder | W21.8-14 | Distribution via service networks |
| ISO ISO tank | approx. 18 t | per ISO tank | ISO tankconnection | and Transport |
Filling Ratioper"", steel cylinderper.
6 Applications
- Low temperature cold storage, and
- and cold-chain logistics
- and equipment
- pharmaceutical and Low temperature
Equipment Compatibility & Charging Advice
- R507 POE, and or.
- R507 Azeotropic Mixture, and, Spillage, Relative Zeotropic refrigerant.
- Low temperaturecompressorperLow temperature refrigerant, liquid injection or suction cooling Discharge temperature.
- R507 GWP 3985, EU F-Gas Regulationsnew equipmentrestricted, Item R452A, R448A or R449A.
- recoverysteel cylinder, and R404A Other refrigerant and.
7 Storage & Transport
- Storage,, ventilation, 40 ℃, ignition source, heat source and.
- steel cylinder, and,,, and.
- R507 Non-flammable, Vapour, Spillagelow-lying areasoxygen, ventilation.
- and oxygen, and (,, )Flammable.
- and, Low 0.05 MPa.
- Transportper Danger 2.2 class, and, steel cylinder.
8 Safety & Handling
- Asphyxiation riskVapour, Spillagelow-lying areas, and cold storageoxygen, ventilationoxygen(Low 19.5 %).
- SpillageSpillageventilation,;;leak detection or leak detection, open flamesleak detection.
- Thermal decomposition riskopen flames or High temperature(approx. 400 ℃ and above), cold storageventilation.
- enclosedcold storage, enclosed confined space, oxygen.
- frostbite ProtectionLiquefied gasfrostbite, and;frostbite 40 ℃.
- Inhalation andVapourasphyxiation and, fresh airoxygen;Eye contact 15.
9 Quality Assurance & Shipping Documents
- Batch COA, Purity( or ), Moisture, Acidity and Evaporation Residue.
- Moisture, and Low temperature.
- 12 months, Batch, No. and.
- perthird-party test report(SGS / ), SDS Description REACH, RoHS.
10 Frequently Asked Questions
R507 and R404A ?
R507 R125 and R143a Azeotropic Mixture( 0 ℃), R404A R134a Near-azeotropic Mixture(approx. 0.8 ℃). R507 Slightly higher, Spillage;Low temperature A1 refrigerant,, charging and.
R507 Can it be topped up after a leak?
. R507 Azeotropic Mixture,, Spillage refrigerant, per,.
R507 GWP 3985 ?
. R507 "Kigali Amendment"phase-down, EU F-Gas Regulations equipment GWP 2500 refrigerant. existing installed base equipment servicing, Item R452A(GWP 1945).
R507 Shelf life?
steel cylinder, Storage, R507 Shelf Life 24 months., steel cylinder and.
Specificationdata Typical,;Parameter Batch COA. and, or or, equipment and Regulations.
| Reviewed by: | Approved by: | Hubei Zhongjin Fluorine Chemical Co., Ltd.
Get R507 Technical Data Sheet & Quotation
Word Specification and, or Direct Contact sales teamGetBatch Test Report and Quotation.