Technical Data Sheet(TDS) R-452A(HFC/HFO blend) CH₂F₂ / CHF₂CF₃ / CF₃CF=CH₂( 11/59/30) R452A, and.

Document No.:ZJ-TDS-R452A-2026 Version:V1.0 Issue date2026-09-24 Next review:2027-09-24

1 Product Identification

Item Value
Product NameR452A Refrigerant
Chemical NameR-452A(HFC/HFO blend)
English NameR-452A(HFC/HFO blend)
Molecular FormulaCH₂F₂ / CHF₂CF₃ / CF₃CF=CH₂( 11/59/30)
Molecular Weightapprox. 103.5
CAS Registry Number75-10-5 / 354-33-6 / 754-12-1
EINECS No.200-839-4 / 206-557-8 / 468-710-7
UN Number3163
Transport Hazard ClassClass 2.2, non-flammable gas
ASHRAE Safety ClassificationA1(Low toxicity, non-flammable)
Reference BasisManufacturer data; the batch COA governs

Reference Basis: Compiled from manufacturer data (safety classification per GB/T 7778, ASHRAE 34 / ISO 817)

2 Physical & Chemical Properties

R452A Typicaldata, system and,.

Item Typical Value
AppearanceColorless, transparent liquefied gas
OdorFaint, non-irritating
Bubble point(101.3 kPa)approx. -47.0 ℃
Temperature glideapprox. 3 ℃(Zeotropic)
Critical Temperatureapprox. 74 ℃
Critical Pressureapprox. 4.00 MPa
Vapor Pressure (25 C, absolute)approx. 1.20 MPa
Liquid Density(25 ℃)approx. 1010 kg/m³
Saturated Vapor Density(25 ℃)approx. 46 kg/m³
Latent heat of vaporisation (at bubble point)approx. 210 kJ/kg
Liquid Specific Heat(25 ℃)approx. 1.45 kJ/(kg K)
Vapor Specific Heat(25 ℃, 101.3 kPa)approx. 0.85 kJ/(kg K)
Liquid Thermal Conductivity(25 ℃)approx. 0.088 W/(m K)
Vapor Thermal Conductivity(25 ℃)approx. 0.0142 W/(m K)
Liquid Viscosity(25 ℃)approx. 0.15 mPa s
Vapor Viscosity(25 ℃)approx. 0.0128 mPa s
Surface Tension(25 ℃)approx. 7.9 mN/m
Water Solubility(25 ℃)Slightly soluble
Auto-Ignition TemperatureNot applicable (non-flammable)
Flammability Limits in Air (vol.%)None (non-flammable)
OEL (8 h TWA)approx. 900 ppm(per)
Ozone Depletion Potential (ODP)0
GWP (100 yr, IPCC AR5)approx. 2140
Atmospheric Lifetimeapprox. 16 years(per)

3 Quality Specifications & Test Methods

R452A Parameter, Batch COA.

Item Parameter Test Method
AppearanceColourless and clear, free of suspended matter and mechanical impuritiesVisual inspection
Purity≥ 99.90 %Gas chromatography GC-FID
Composition tolerance±1.0 %Gas chromatography GC-FID
Moisture≤ 10 ppmKarl Fischer coulometric method
Acidity( HF )≤ 0.1 ppmAlkali absorption - potentiometric titration
Evaporation Residue≤ 0.01 %Gravimetric method
Non-Condensable Gas(, 25 ℃)≤ 1.5 %Gas chromatography
(Cl⁻)Negative (pass)Silver nitrate turbidimetry

4 Comparison with Common Refrigerants

Comparison Item R452A(this product) R404A R507
CompositionR32/R125/R1234yf 11/59/30R125/R143a/R134a 44/52/4R125/R143a 50/50
ODP000
GWP(100 years, AR5)194539223985
ASHRAE Safety ClassificationA1A1A1
Temperature glideapprox. 3 ℃approx. 0.8 ℃0 ℃(Azeotropic)
Relative cooling capacityand R404ABaseline 100 %Slightly higher, approx. +2 % ~ +5 %
Relative COPR404ABaselineSlightly higher
compressor Discharge temperatureSlightly higher than R404ABaselineSlightly higher
Compatible lubricantPOEPOEPOE
Retrofit feasibilityR404A low-GWPOriginal fluid in existing systemsLow temperaturesystem
Current selectionR404A low-GWPEUrestrictednew equipmentEUrestrictednew equipment

5 Packaging Specifications

Package Type Specification Filling Ratio Valve Connection Application
disposable cylinder10.9 kg(customizable 9.5 kg)≤ 0.85 kg/LW21.8-14(customizable CGA / DIN)Servicing and small-batch use
steel cylinder400 kg(T )≤ 0.85 kg/LW21.8-14Bulk project supply
cylinder pallet12 × 10.9 kgPer cylinderW21.8-14Distribution via service networks
ISO ISO tankapprox. 18 tper ISO tankISO tankconnectionand Transport

Filling Ratioper"", steel cylinderper.

6 Applications

  • Low temperature cold storage, and
  • and Transport
  • and cold-chain logistics equipment
  • R404A / R507 system low-GWP retrofit

Equipment Compatibility & Charging Advice

  • R452A POE, retrofit R404A system POE,.
  • Zeotropic Mixture(approx. 3 ℃), charging, Spillagerecoverycharging.
  • Discharge temperature Slightly higher than R404A, retrofitcompressor Discharge temperature, liquid injection or suction cooling.
  • chargingLow R404A, per equipment.
  • retrofitrecovery refrigerant, and R404A, R507 refrigerantcharging.

7 Storage & Transport

  • Storage,, ventilation, 40 ℃, ignition source, heat source and.
  • steel cylinder, and,,, and.
  • R452A A1 Non-flammable refrigerant, Vapour, Spillagelow-lying areasoxygen, ventilation.
  • and oxygen, and (,, )Flammable.
  • and, Low 0.05 MPa.
  • Transportper Danger 2.2 class, and, steel cylinder.

8 Safety & Handling

  • Asphyxiation riskVapour, Spillagelow-lying areas, and cold storageoxygen, ventilationoxygen(Low 19.5 %).
  • SpillageSpillageventilation,;;leak detection or leak detection, open flamesleak detection.
  • Thermal decomposition riskopen flames or High temperature(approx. 400 ℃ and above), cold storageventilation.
  • enclosedcold storage, enclosed confined space, oxygen.
  • frostbite ProtectionLiquefied gasfrostbite, and;frostbite 40 ℃.
  • Inhalation andVapourasphyxiation and, fresh airoxygen;Eye contact 15.

9 Quality Assurance & Shipping Documents

  • Batch COA, Purity( or ), Moisture, Acidity and Evaporation Residue.
  • Moisture, and Low temperature.
  • 12 months, Batch, No. and.
  • perthird-party test report(SGS / ), SDS Description REACH, RoHS.

10 Frequently Asked Questions

Why is R452A R404A?

R404A GWP 3922, EU F-Gas Regulations equipment GWP 2500 refrigerant. R452A GWP 1945, and and R404A, A1 Non-flammable, retrofitLow Alternatives.

R452A retrofit R404A systemcompressor?

. R452A and R404A and, POE;Mainrecovery refrigerant,, percharging. Discharge temperature Slightly higher, compressor Discharge temperature.

R452A Can it be topped up after a leak?

. R452A Zeotropic Mixture(approx. 3 ℃), Spillage,. recovery refrigerant, percharging.

R452A Shelf life?

steel cylinder, Storage, R452A Shelf Life 24 months., steel cylinder and.

Disclaimer
Specificationdata Typical,;Parameter Batch COA. and, or or, equipment and Regulations.

| Reviewed by: | Approved by: | Hubei Zhongjin Fluorine Chemical Co., Ltd.

Get R452A Technical Data Sheet & Quotation

Word Specification and, or Direct Contact sales teamGetBatch Test Report and Quotation.