Home / Products / R407C / Specification

R407C Refrigerant Specification

Technical Data Sheet(TDS) R-407C(HFC blend) CH₂F₂ / CHF₂CF₃ / CH₂FCF₃( 23/25/52) R407C, and.

Document No.:ZJ-TDS-R407C-2026 Version:V1.0 Issue date2026-09-24 Next review:2027-09-24

1 Product Identification

Item Value
Product NameR407C Refrigerant
Chemical NameR-407C(HFC blend)
English NameR-407C(HFC blend)
Molecular FormulaCH₂F₂ / CHF₂CF₃ / CH₂FCF₃( 23/25/52)
Molecular Weight86.20
CAS Registry Number75-10-5 / 354-33-6 / 811-97-2
EINECS No.200-839-4 / 206-557-8 / 212-377-0
UN Number3340
Transport Hazard ClassClass 2.2, non-flammable gas
ASHRAE Safety ClassificationA1(Low toxicity, non-flammable)
Reference BasisManufacturer data; the batch COA governs

Reference Basis: Compiled from manufacturer data (safety classification per GB/T 7778, ASHRAE 34 / ISO 817)

2 Physical & Chemical Properties

R407C Typicaldata, system and,.

Item Typical Value
AppearanceColorless, transparent liquefied gas
OdorSlight ethereal odor, non-irritating
Bubble point(101.3 kPa)-43.8 ℃
(101.3 kPa)-36.7 ℃
Temperature glideapprox. 7.1 ℃(Zeotropic)
Critical Temperature86.0 ℃
Critical Pressure4.63 MPa
Critical Densityapprox. 480 kg/m³
Vapor Pressure (25 C, absolute)1.19 MPa
Liquid Density(25 ℃)1136 kg/m³
Saturated Vapor Density(25 ℃)41.5 kg/m³
Latent heat of vaporisation (at bubble point)approx. 250 kJ/kg
Liquid Specific Heat(25 ℃)1.55 kJ/(kg·K)
Vapor Specific Heat(25 ℃, 101.3 kPa)0.85 kJ/(kg·K)
Liquid Thermal Conductivity(25 ℃)0.099 W/(m·K)
Vapor Thermal Conductivity(25 ℃)0.0140 W/(m·K)
Liquid Viscosity(25 ℃)0.16 mPa·s
Vapor Viscosity(25 ℃)0.0128 mPa·s
Surface Tension(25 ℃)8.5 mN/m
Water Solubility(25 ℃)Slightly soluble
Auto-Ignition TemperatureNot applicable (non-flammable)
Flammability Limits in Air (vol.%)None (non-flammable)
OEL (8 h TWA)1000 ppm
Ozone Depletion Potential (ODP)0
GWP (100 yr, IPCC AR5)1774
Atmospheric Lifetimeapprox. 15 years(per)

3 Quality Specifications & Test Methods

R407C Parameter, Batch COA.

Item Parameter Test Method
AppearanceColourless and clear, free of suspended matter and mechanical impuritiesVisual inspection
Purity≥ 99.90 %Gas chromatography GC-FID
Composition toleranceR32 ±1.0 %, R125 ±1.0 %, R134a ±1.0 %Gas chromatography GC-FID
Moisture≤ 10 ppmKarl Fischer coulometric method
Acidity( HCl )≤ 0.1 ppmAlkali absorption - potentiometric titration
Evaporation Residue≤ 0.01 %Gravimetric method
Non-Condensable Gas(, 25 ℃)≤ 1.5 %Gas chromatography
(Cl⁻)Negative (pass)Silver nitrate turbidimetry

4 Comparison with Common Refrigerants

Comparison Item R407C(this product) R22 R410A
CompositionR32/R125/R134a 23/25/52Single compound CHClF₂R32/R125 50/50
ODP00.0550
GWP(100 years, AR5)177418102088
ASHRAE Safety ClassificationA1A1A1
Temperature glideapprox. 7.1 ℃(Zeotropic)0 ℃< 0.2 ℃
Operating pressureand R22Baselineapprox. R22 1.6
Relative COPLow, approx. -3 % ~ -6 %BaselineSlightly higher
Compatible lubricantPOEMineral oil / alkylbenzenePOE
Retrofit feasibilityR22 systemretrofitOriginal fluid in existing systems—
Current selectionR22 Medium temperaturesystemquotacontrol, existing installed base servicingand air conditioning

5 Packaging Specifications

Package Type Specification Filling Ratio Valve Connection Application
disposable cylinder9.5 kg(customizable 11.3 kg)≤ 0.95 kg/LW21.8-14(customizable CGA / DIN)Servicing and small-batch use
steel cylinder400 kg(T )≤ 0.95 kg/LW21.8-14Bulk project supply
cylinder pallet12 × 9.5 kgPer cylinderW21.8-14Distribution via service networks
ISO ISO tankapprox. 18 tper ISO tankISO tankconnectionand Transport

Filling Ratioper"", steel cylinderper.

6 Applications

  • R22 air conditioning and heat pumpsystem retrofit
  • air conditioning, air conditioning and
  • Medium temperature cold storage and commercial refrigerationunit
  • chiller and processsystem

Equipment Compatibility & Charging Advice

  • R407C POE, R22.
  • R407C Zeotropic Mixture, Temperature glideapprox. 7 ℃, charging, charging.
  • R22 and, and charging,.
  • system Spillage, recovery refrigerantpercharging,.
  • retrofitcompressor, and and POE HFC refrigerant.

7 Storage & Transport

  • Storage,, ventilation, 40 ℃, ignition source, heat source and.
  • steel cylinder, and,,, and.
  • R407C Non-flammable, Vapour, Spillagelow-lying areasoxygen, ventilation.
  • and oxygen, and (,, )Flammable.
  • and, Low 0.05 MPa.
  • Transportper Danger 2.2 class, and, steel cylinder.

8 Safety & Handling

  • Asphyxiation riskVapour, Spillagelow-lying areas, and equipmentoxygen, ventilationoxygen(Low 19.5 %).
  • SpillageSpillageventilation,;;leak detection or leak detection, open flamesleak detection.
  • —Zeotropic MixtureSpillage,, recoverycharging.
  • Thermal decomposition riskopen flames or High temperature(approx. 400 ℃ and above), ventilation.
  • frostbite ProtectionLiquefied gasfrostbite, and;frostbite 40 ℃.
  • Inhalation andVapourasphyxiation and, fresh airoxygen;Eye contact 15.

9 Quality Assurance & Shipping Documents

  • Batch COA, Purity( or ), Moisture, Acidity and Evaporation Residue.
  • Moisture, and Low temperature.
  • 12 months, Batch, No. and.
  • perthird-party test report(SGS / ), SDS Description REACH, RoHS.

10 Frequently Asked Questions

R407C Can it directly replace R22 ?

retrofit. R407C and and R22, R22 Medium temperaturesystem Alternatives; POE,, and charging. retrofit R22 systemLow 3 % ~ 6 %.

Why is R407C charging?

R407C Zeotropic Mixture, Temperature glideapprox. 7 ℃. steel cylindercharging, LowBoiling point(R32), system,,. charging.

R407C Can it be topped up after a leak?

. Zeotropic MixtureSpillage, system refrigerant,. recovery refrigerant,, percharging.

R407C Shelf life?

steel cylinder, Storage, R407C Shelf Life 24 months., steel cylinder and.

Disclaimer
Specificationdata Typical,;Parameter Batch COA. and, or or, equipment and Regulations.

| Reviewed by: | Approved by: | Hubei Zhongjin Fluorine Chemical Co., Ltd.

Get R407C Technical Data Sheet & Quotation

Word Specification and, or Direct Contact sales teamGetBatch Test Report and Quotation.