Home / Products / R236fa / Specification

R236fa Refrigerant Technical Data Sheet

Technical Data Sheet(TDS) 1,1,1,3,3,3-Hexafluoropropane(HFC-236fa) C₃H₂F₆ R236fa, and.

Document No.:ZJ-TDS-R236FA-2026 Version:V1.0 Issue date2026-09-24 Next review:2027-09-24

1 Product Identification

Item Value
Product NameR236fa Refrigerant
Chemical Name1,1,1,3,3,3-Hexafluoropropane(HFC-236fa)
English Name1,1,1,3,3,3-Hexafluoropropane(HFC-236fa)
Molecular FormulaC₃H₂F₆
Molecular Weight152.04
CAS Registry Number431-63-0
EINECS No.207-001-9
UN Number3163
Transport Hazard ClassClass 2.2, non-flammable gas
ASHRAE Safety ClassificationA1(Low toxicity, non-flammable)
Reference BasisManufacturer data; the batch COA governs

Reference Basis: Compiled from manufacturer data (safety classification per GB/T 7778, ASHRAE 34 / ISO 817)

2 Physical & Chemical Properties

R236fa Typicaldata, system and,.

Item Typical Value
AppearanceColorless, transparent liquefied gas
OdorFaint, non-irritating
Boiling Point (101.3 kPa)-1.4 ℃
Freezing Pointapprox. -94 ℃
Critical Temperature130.2 ℃
Critical Pressureapprox. 3.20 MPa
Vapor Pressure (25 C, absolute)approx. 0.29 MPa
Liquid Density(25 ℃)approx. 1360 kg/m³
Saturated Vapor Density(25 ℃)approx. 17 kg/m³
Latent Heat of Vaporization (at boiling point)approx. 152 kJ/kg
Liquid Specific Heat(25 ℃)approx. 1.28 kJ/(kg K)
Vapor Specific Heat(25 ℃, 101.3 kPa)approx. 0.85 kJ/(kg K)
Liquid Thermal Conductivity(25 ℃)approx. 0.072 W/(m K)
Vapor Thermal Conductivity(25 ℃)approx. 0.0125 W/(m K)
Liquid Viscosity(25 ℃)approx. 0.30 mPa s
Vapor Viscosity(25 ℃)approx. 0.0116 mPa s
Surface Tension(25 ℃)approx. 8.4 mN/m
Water Solubility(25 ℃)Slightly soluble
Auto-Ignition TemperatureNot applicable (non-flammable)
Flammability Limits in Air (vol.%)None (non-flammable)
OEL (8 h TWA)approx. 500 ppm(perdata)
Ozone Depletion Potential (ODP)0
GWP (100 yr, IPCC AR5)9810
Atmospheric Lifetimeapprox. 242 years

3 Quality Specifications & Test Methods

R236fa Parameter, Batch COA.

Item Parameter Test Method
AppearanceColourless and clear, free of suspended matter and mechanical impuritiesVisual inspection
Purity≥ 99.90 %Gas chromatography GC-FID
Moisture≤ 10 ppmKarl Fischer coulometric method
Acidity( HF )≤ 0.1 ppmAlkali absorption - potentiometric titration
Evaporation Residue≤ 0.01 %Gravimetric method
Non-Condensable Gas(, 25 ℃)≤ 1.5 %Gas chromatography
(olefin)≤ 10 ppmGas chromatography
(Cl⁻)Negative (pass)Silver nitrate turbidimetry

4 Comparison with Common Refrigerants

Comparison Item R236fa(this product) R227ea R245fa
CompositionSingle compound C₃H₂F₆Single compound C₃HF₇Single compound C₃H₃F₅
Boiling point-1.4 ℃-16.4 ℃15.3 ℃
ODP000
GWP(100 years, AR5)981032201030
ASHRAE Safety ClassificationA1(Non-flammable)A1(Non-flammable)B1
Vapor Pressure(25 ℃)approx. 0.29 MPaapprox. 0.39 MPaapprox. 0.148 MPa
Typical useFirefighting, ORC refrigerant, equipmentFirefightingORC and High temperatureheat pump
Current selectionspeciality Firefighting and, perordersupplyFirefightingHigh temperatureheat pump and ORC

5 Packaging Specifications

Package Type Specification Filling Ratio Valve Connection Application
disposable cylinder40 kg(customizable 20 kg)≤ 1.15 kg/LW21.8-14(customizable CGA / DIN)Firefightingsystem, small-batch
steel cylinder250 kg(customizable 400 kg)≤ 1.15 kg/LW21.8-14Bulk project supply
cylinder palletMade to orderPer cylinderW21.8-14Itemdistribution
ISO ISO tankapprox. 20 tper ISO tankISO tankconnectionand Transport

Filling Ratioper"", steel cylinderper.

6 Applications

  • Firefightingsystem
  • Organic Rankine Cycle(ORC)refrigerant
  • equipment and
  • speciality and

Equipment Compatibility & Charging Advice

  • R236fa A1 Non-flammable refrigerant, Firefighting and usepersystem and.
  • ORC refrigerant or, and.
  • and, testing.
  • GWP refrigerant(9810), recovery and, emissions;Itemlow-GWP Alternatives.
  • and equipment, ventilationoxygen.

7 Storage & Transport

  • Storage,, ventilation, 40 ℃, ignition source, heat source and.
  • steel cylinder, and,,, and.
  • R236fa A1 Non-flammable refrigerant, Vapour, Spillagelow-lying areasoxygen, ventilation.
  • and oxygen, and (,, )Flammable.
  • and, Low 0.05 MPa.
  • Transportper Danger 2.2 class, and, steel cylinder.

8 Safety & Handling

  • Asphyxiation riskVapour, Spillagelow-lying areas, and oxygen, ventilationoxygen(Low 19.5 %).
  • Firefighting RiskFirefightingdecomposition products,, ventilation.
  • SpillageSpillageventilation,;;leak detection.
  • Thermal decomposition riskopen flames or High temperature, ventilation.
  • frostbite ProtectionLiquefied gasfrostbite, and;frostbite 40 ℃.
  • Inhalation andVapour and, fresh airoxygen;Eye contact 15.

9 Quality Assurance & Shipping Documents

  • Batch COA, Purity( or ), Moisture, Acidity and Evaporation Residue.
  • Moisture, and Low temperature.
  • 12 months, Batch, No. and.
  • perthird-party test report(SGS / ), SDS Description REACH, RoHS.

10 Frequently Asked Questions

R236fa and R227ea FirefightingHow to choose?

Non-flammable, no residue, non-conductive. R227ea(GWP 3220)Firefightingsystem, supply and;R236fa(GWP 9810) and equipment., and system Supplier.

R236fa Can it be used as an immersion cooling fluid?

. R236fa Non-flammable,, cooling medium. testing(, PCB, ), and.

R236fa GWP 9810 What is the impact?

GWP refrigerant, HFC phase-down., recovery, and Spillage, and control.

R236fa Shelf life?

steel cylinder, Storage, R236fa Shelf Life 24 months., steel cylinder and.

Disclaimer
Specificationdata Typical,;Parameter Batch COA. and, or or, equipment and Regulations.

| Reviewed by: | Approved by: | Hubei Zhongjin Fluorine Chemical Co., Ltd.

Get R236fa Technical Data Sheet & Quotation

Word Specification and, or Direct Contact sales teamGetBatch Test Report and Quotation.