Home / Products / R161 / Specification

R161 Refrigerant Technical Data Sheet

Technical Data Sheet(TDS) Fluoroethane(Refrigerant R 161) CH₃CH₂F R161, and.

Document No.:ZJ-TDS-R161-2026 Version:V1.0 Issue date2026-10-20 Next review:2027-10-20

1 Product Identification

Item Value
Product NameR161 Refrigerant
Chemical NameFluoroethane(Refrigerant R 161)
English NameFluoroethane(Refrigerant R 161)
Molecular FormulaCH₃CH₂F
Molecular Weight48.06
CAS Registry Number353-36-6
UN Number2453
Transport Hazard ClassClass 2.1, flammable gas
ASHRAE Safety ClassificationA3(Low toxicity, flammable)
Reference BasisManufacturer data; the batch COA governs

Reference Basis: Compiled from manufacturer data (safety classification per GB/T 7778, ASHRAE 34 / ISO 817)

2 Physical & Chemical Properties

R161 Typicaldata, system and,.

Item Typical Value
AppearanceColorless, transparent liquefied gas
OdorSlight ethereal odour
Boiling Point (101.3 kPa)-37.1 ℃
Freezing Point-143.2 ℃
Critical Temperatureapprox. 102.2 ℃
Critical Pressureapprox. 5.03 MPa
Vapor Pressure(20 ℃, )approx. 0.79 MPa
Liquid Density(Boiling point)approx. 818 kg/m³
Saturated Vapor Densityapprox. 2.19 kg/m³
Latent Heat of Vaporization (at boiling point)approx. 421 kJ/kg
Relative(=1)approx. 1.7
Water Solubility(25 ℃)Slightly soluble(0.04 mol/L)
Auto-Ignition Temperatureapprox. 600 ℃
Flash pointapprox. -91 ℃
Flammability Limits in Air (vol.%)approx. 3.8 % ~ 10.0 %
Minimum ignition energyapprox. 0.31 mJ
OEL (8 h TWA)( ACGIH )
Ozone Depletion Potential (ODP)0
Global warming potential (GWP) GWP(100 years)approx. 12
Atmospheric Lifetimeapprox. 0.3 years

3 Quality Specifications & Test Methods

R161 Parameter, Batch COA.

Item Parameter Test Method
AppearanceColourless and clear, free of suspended matter and mechanical impuritiesVisual inspection
Purity≥ 99.50 %Gas chromatography GC-FID
Moisture≤ 20 ppmKarl Fischer coulometric method
Acidity( HCl )≤ 0.2 ppmAlkali absorption - potentiometric titration
Evaporation Residue≤ 0.02 %Gravimetric method
Non-Condensable Gas≤ 1.5 %Gas chromatography
(Cl⁻)Negative (pass)Silver nitrate turbidimetry

4 Comparison with Common Refrigerants

Comparison Item R161(this product) R22 R152a
CompositionSingle compound CH₃CH₂FSingle compound CHClF₂Single compound CH₃CHF₂
Boiling point-37.1 ℃-40.8 ℃-24.0 ℃
Critical Temperatureapprox. 102.2 ℃approx. 112.0 ℃approx. 113.3 ℃
ODP0approx. 0.0550
GWP(100 years)approx. 12approx. 1,810approx. 124
ASHRAE Safety ClassificationA3(Flammable)A1 (non-flammable)A2L(Mildly flammable)
Flammability limits in airapprox. 3.8 % ~ 10.0 %Non-flammableapprox. 4.8 % ~ 20.6 %
Relative chargeapprox. R22 55 %Baseline 100 %approx. R22 62 %
Typical useR407C/R410Aair conditioning and processfoam blowing and Low temperature
Current selectionultra-low-GWPSubject to quota phase-downSubject to quota phase-down

5 Packaging Specifications

Package Type Specification Filling Ratio Valve Connection Application
disposable cylinder25 kg(customizable 10 kg)≤ 0.50 kg/LW21.8-14 / CGA(perorder)Servicing and trial quantities
steel cylinder400 kg≤ 0.50 kg/LW21.8-14Item and supply
cylinder palletMade to orderPer cylinderW21.8-14Itemdistribution
ISO ISO tankMade to orderper ISO tankISO tankconnectionTransport

Filling Ratioper"", steel cylinderper.

6 Applications

  • R407C / R410A
  • Medium temperatureair conditioning and heat pumpLow temperature
  • Low temperaturefoam blowingformulation
  • feedstock for fluorine fine chemicals

Equipment Compatibility & Charging Advice

  • R161 Boiling point -37.1 ℃, GWP approx. 12, and R22, R407C/R410A Low.
  • R161 A3 Flammable refrigerant, approx. 3.8 %, systemperexplosion-proof: explosion-proof,, ventilation and Flammable.
  • refrigerantcharging and, application.
  • Critical Temperatureapprox. 102 ℃,, steel cylinder Higher, Storage.
  • and, POE;system, and and refrigerant.

7 Storage & Transport

  • Storage,, ventilation, 30 ℃, ignition source, heat source and.
  • steel cylinder, and,,, and.
  • 2.1 class Flammable, perexplosion-proof equipment, Flammable and explosion-proofventilation.
  • and oxygen,, Flammable, explosion-proof and.
  • and, Low 0.05 MPa.
  • Transportper Danger 2.1 class, Firefighting and, and.

8 Safety & Handling

  • Flammability and explosion riskR161 A3 Flammable refrigerant, Flammability limitapprox. 3.8 % ~ 10.0 %,, explosion-proof, ventilation.
  • Spillageignition sourceventilation,;Vapour, low-lying areas;explosion-proof and.
  • Firefightingcarbon dioxide or Firefighting, steel cylinder. Spillage Flame,.
  • Overpressure riskCritical Temperatureapprox. 102 ℃,,, Keep away from heat.
  • frostbite ProtectionLiquefied gasfrostbite, and;frostbite 40 ℃.
  • Inhalation andVapourasphyxiation, and, fresh airoxygen;Eye contact 15.

9 Quality Assurance & Shipping Documents

  • Batch COA, Purity( or ), Moisture, Acidity and Evaporation Residue.
  • Moisture, and Low temperature.
  • 12 months, Batch, No. and.
  • perthird-party test report(SGS / ), SDS Description REACH, RoHS.

10 Frequently Asked Questions

R161 What type of refrigerant is it?

R161(Fluoroethane(Refrigerant R 161), CH₃CH₂F) HFC classultra-low-GWP Refrigerant, ODP, GWP approx. 12, Boiling point -37.1 ℃, A3 Flammable refrigerant. refrigerant Medium temperature, R407C, R410A Alternatives Low.

R161 Can it replace R22 ?

R161 and R22, GWP Low R22, R22 refrigerant. R161 A3 Flammable refrigerant, perexplosion-proofretrofit, application R161 refrigerant, equipment and.

R161 and R152a What is the difference?

C₂, GWP Low, Flammable and. R152a Boiling point -24.0 ℃, A2L;R161 Boiling point -37.1 ℃, A3, Flammable Boiling pointLow. LowEvaporating temperature R161, explosion-proof.

Disclaimer
Specificationdata Typical,;Parameter Batch COA. and, or or, equipment and Regulations.

| Reviewed by: | Approved by: | Hubei Zhongjin Fluorine Chemical Co., Ltd.

Get R161 Technical Data Sheet & Quotation

Word Specification and, or Direct Contact sales teamGetBatch Test Report and Quotation.